Time your pump, then size the backup
Runtime claims for battery backup sump pumps disagree because they hide the one number that matters: how much water reaches your pit. This calculator gets it from your own pump. Time how long it runs and how often it starts, give the pit size, and the water coming in is the pit volume per cycle divided by the time it takes to refill.
A 12 V backup pump usually moves less water than the main pump, so it runs a bigger share of the time: water coming in divided by its flow at your lift. Its amps times that share is the battery it uses each hour. Battery makers say to plan on using only part of the rated amp-hours: about half for AGM (Battle Born, Trojan) and 80 to 100% for lithium (Battle Born). The calculator starts at 0.50 and 0.80 and lets you change them. Not every backup takes lithium: Basement Watchdog says its systems do not.
If you would rather keep your main pump running, a power station has to supply its running watts for the share of time it runs, plus the surge to start the motor. A water-powered backup needs city water pressure and an approved backflow device, and a generator handles the whole house for days, outdoors only.
Figures we could not confirm
No published figure gives how much faster a pit fills in a storm, how quickly a standby battery loses capacity with age, or one usable share for every battery; those are editable assumptions, labelled where they appear. The "gallons per charge" ratings quoted for many backups turned up only on retailer and review pages in our research, not on the maker pages we read, so we do not use them. WAYNE's ESP25 page gives no amp draw. We did not check Canadian rules for water-powered backups or the amounts of municipal flood subsidies; ask your municipality.
Sources
- Intact Centre on Climate Adaptation, Basement Flood Protection Checklist and Three Steps to Cost-Effective Home Flood Protection. Spring and fall tests, backup pump and battery, flood alarms, discharge 2 m from the foundation, municipal subsidies.
- CREA, Tips to protect your clients' home from flooding (quotes an Intact Centre report: bucket test; back-up battery for up to 72 hours).
- Ontario Building Code 2024 (O. Reg. 163/24), Division B, Article 9.14.5.2 Sump Pits.
- Basement Watchdog Emergency, Special CONNECT and Big Dog CONNECT specifications, FAQs and Emergency manual. Amps and flow at 10 ft, runtimes at a 10% duty cycle, no lithium, check valves, charge times, battery replacement.
- WAYNE ESP25 and its manual. 26 hours at 5 US gal a minute with a 75 Ah battery, check valve, GFCI, monthly battery check, alarm tones.
- Liberty Pumps SJ10 SumpJet and its manual. Water-powered flow chart, 2 gallons out per gallon used, pressure range, backflow device, wells.
- Battle Born Batteries, AGM vs lithium (a lithium maker's blog) and Trojan Battery FAQs (a lead-acid maker). Usable share of rated capacity.
- Champion Power Equipment, Generator Wattage Chart. Sump pump running and starting watts.
- Anker SOLIX, How long will a power station last (a maker's blog). About 85% of rated Wh reaches AC devices.
- Public Safety Canada, Get Prepared: Power outages. Generator outdoors at least 6 m from the house, transfer switch, wet hands and the panel.
All pages read and checked on November 16, 2026. Maker figures are the maker's own claims. In an emergency, call 911.
About Sump Pump Battery Backup Calculator
A sump pump battery backup runs for its usable battery amp-hours divided by the amp-hours its pump uses each hour, so time one pump cycle first. At 10 seconds of pumping every 5 minutes from an 18 in pit, about 82 US gal (311 L) comes in an hour; a 9.5 A backup pump that moves 1,000 GPH runs 8.2% of the time and uses 0.78 Ah an hour, so a 75 Ah AGM battery at 50% usable lasts about 48 hours. The Intact Centre advises testing the sump pump and backup power every spring and fall.
By the ToolFluency team · Updated November 2026
Time how long your sump pump runs and how often it starts, give the pit size, and pick your backup: a 12 V battery backup pump, a power station or inverter on your main pump, a water-powered backup, or a generator. You get the water coming in, how much of the time the backup runs, how many hours your battery lasts, and the battery you need for a 12 to 72 hour outage, AGM or lithium, at the flow you timed and in a storm. Every maker figure and every assumption is labelled.
How to size a sump pump battery backup
- With a phone timer, time how many seconds your sump pump runs and the minutes from one start to the next. Or count the starts in 15 minutes: 15 / starts = minutes between starts.
- Measure the pit across the inside and how far the water drops each time the pump runs.
- Guess how many times faster it cycles in a storm or spring melt. Time it in the next heavy rain to replace the guess.
- Pick your backup. For a 12 V backup pump, use its amps and flow at your lift from the spec sheet. For a power station, use the main pump's watts.
- Choose the outage length and the battery type: AGM or lithium. Use the usable share and battery health shown, or your own.
- Read the battery size, or switch to "I have one" to see how long yours lasts. Then check the test schedule, the check valve and the high-water alarm below.
Battery for a 24-hour outage: 9.5 A, 1,000 GPH backup pump, 18 in pit, water drops 6 in
| Pump timing | Water in an hour | Backup running | AGM (0.50 usable) | Lithium (0.80 usable) |
| 10 s every 5 min | 82 US gal (311 L) | 8.2% | 37.5 Ah | 23.4 Ah |
| 10 s every 5 min, storm x4 | 328 US gal (1,242 L) | 32.8% | 149.7 Ah | 93.6 Ah |
| 15 s every minute (wet spring) | 529 US gal (2,002 L) | 52.9% | 241.2 Ah | 150.7 Ah |
Examples
A pump that runs 10 seconds every 5 minutes
An 18 in pit that drops 6 in holds pi x 9 x 9 x 6 / 231 = 6.61 US gal a cycle. It refills in 290 s, so 6.61 / 290 x 3,600 = 82 US gal (311 L) comes in an hour, and the main pump runs 10 / 300 = 3.3% of the time. A 9.5 A backup that moves 1,000 GPH runs 82 / 1,000 = 8.2% of the time and uses 9.5 x 0.082 = 0.78 Ah an hour, 224 Wh a day. A 75 Ah AGM battery at 0.50 usable lasts 37.5 / 0.78 = about 48 hours; at lithium's 0.80, about 77 hours.
A wet spring: 15 seconds every minute
The same pit refills in 45 s, so 6.61 / 45 x 3,600 = 529 US gal (2,002 L) comes in an hour. The 9.5 A backup runs 52.9% of the time and uses 5.02 Ah an hour: a 75 Ah AGM battery lasts about 7.5 hours, a 75 Ah lithium about 11.9. In a storm at 4 times that flow, 2,115 US gal an hour comes in, more than the backup's 1,000 GPH: it runs nonstop and the pit still rises. On a power station, a 1/3 HP main pump at 800 W running a quarter of the time needs 5,647 Wh for 24 hours, past practical sizes, so a generator is the answer.
Sizing for a 24-hour outage, AGM vs lithium
From the first example, 0.78 Ah an hour x 24 h / 0.50 usable = 37.5 Ah of AGM, the 50 Ah size; at 0.80 usable, lithium needs 23.4 Ah, the 35 Ah size. Sized for a storm at 4 times the flow (3.12 Ah an hour), it is 149.7 Ah of AGM (150 Ah) against 93.6 Ah of lithium (100 Ah). Use lithium only if your backup pump's maker supports it.
Frequently asked questions
How long will a sump pump battery backup run?
Its usable battery amp-hours divided by the amp-hours the pump uses each hour, and that depends on how much water reaches your pit. With 10 seconds of pumping every 5 minutes from an 18 in pit, about 82 US gal (311 L) comes in an hour. A 9.5 A backup pump that moves 1,000 GPH runs 8.2% of the time and uses 0.78 Ah an hour, so a 75 Ah AGM battery at 50% usable lasts about 48 hours. In a wet spring it can be a few hours.
How long does a sump pump battery last?
Two answers. In one outage, it depends on your inflow: time a pump cycle and use the calculator. In years, Basement Watchdog says to replace a battery that is more than 5 years old and to have a weak one load-tested at an auto parts or battery store. The Intact Centre advises testing the sump pump, the backup power and the flood alarms every spring and fall.
How many hours does a battery backup sump pump last?
Maker figures: Basement Watchdog rates its Emergency at 80 hours, Special CONNECT at 48 hours and Big Dog CONNECT at 40 hours on one battery, based on the pump running 10% of the time. WAYNE says its ESP25 runs up to 26 continuous hours at 5 US gal a minute with its 75 Ah battery. Your hours depend on how often your pit fills.
How long does a sump pump battery take to charge?
It depends on the charger. Basement Watchdog says its Big Dog's 20 A charger recharges a flat battery in about 6 hours, its Special's 1.6 A charger can take up to 3 days, and its Emergency model may need 24 to 48 hours after a long run. Check your own manual.
Why is my sump pump battery backup beeping?
It depends on the brand, so check the manual. On WAYNE's ESP25, a 3-second tone sounds each time the backup starts, a 30-second tone when the power goes off, and chirping with a red light means the battery needs attention or replacing.
What size power station do I need for a sump pump?
Take the pump's running watts times the share of time it runs, times the outage hours, divided by 0.85 (Anker SOLIX's figure for losses). A 1/3 HP pump at 800 W (Champion) running 10 seconds every 5 minutes averages 26.7 W, so a 24-hour outage needs about 753 Wh, and the station must handle about 1,600 W to start the motor. It covers a power outage only, not a failed pump.
Can I use a lithium battery for a sump pump backup?
Only if the backup pump's maker supports it, because the charger must suit the battery. Basement Watchdog says its systems do not support lithium-ion batteries. Where it is supported, more of a lithium battery is usable: Battle Born, a lithium maker, gives 80 to 100% for LiFePO4 against about 50% for AGM, so a smaller lithium battery covers the same hours.
Does a water-powered backup sump pump work?
It runs on city water pressure with no battery. Liberty's SJ10 removes about 2 gallons for every gallon of city water and accepts 20 to 100 psi, with 30 psi recommended. It does not work on a private well in an outage. Sump water must never get back into drinking water: Liberty says the Uniform Plumbing Code and some US states require a reduced-pressure (RP/RPZ) backflow device, so ask your municipality or water utility first.
Disclaimer: Estimates from your own timing, your pit size and maker figures, checked against the sources on 2026-11-16. The usable battery share, battery health and storm flow are assumptions you can change. Follow your pump's manual and your local plumbing and electrical rules, and call a licensed electrician or plumber for wiring and plumbing work. If water is on the floor, stay out of it and away from the panel.
Part of ToolFluency’s library of free online tools for Emergency Prep. No account needed, no data leaves your device.