Off-Grid Solar Calculator

Parts for an off-grid solar system

Links go to Amazon. As an Amazon Associate, ToolFluency earns from qualifying purchases.

Sized for the darkest month

An off-grid system has to keep up on the worst days, not the average ones. So the calculator starts from what you run each day, adds what the inverter loses and draws just by being on for anything on 120 V (12 V loads run straight from the battery), and sizes the battery to carry that through the days with no sun you pick. LiFePO4 is used to 80% of its rating and lead-acid to 50%, and a year-round lead-acid bank also loses about a fifth of its capacity in the cold.

Then the panels have to put it all back. Year-round, they are sized on the darkest month where you are, with the panels tilted at your latitude + 15 degrees; summer only, on the darkest of June, July and August at latitude tilt. Both sun figures come from long-term averages: Natural Resources Canada for Canadian places and NREL for US stations. Each panel watt is then cut for real-world losses: PVWatts' default 14% (dirt, wiring, mismatch and more) plus heat and sun angle, taken from our PVWatts runs for Ottawa and Phoenix, and the charge controller.

The charge controller is sized at panel watts / battery volts (check the maker's maximum PV watts at your battery voltage), and the inverter at everything running at once x 1.25, with a surge that covers the biggest motor start. Every count is rounded up to a whole part.

Figures we could not confirm

The loss factors 0.83 (year-round) and 0.74 (summer) are the lower of two PVWatts runs we did, Ottawa and Phoenix, not a published figure. Inverter efficiency 0.90, charge controller 0.95, lead-acid used to 50%, the 1.25 inverter margin, the 2x inverter surge, the class T fuse at 1.25 x inverter current, the 12 V water pump at 100 W for 30 minutes, and counting the inverter's idle draw only for the hours of your longest 120 V load (all day once one runs 12 hours or more) are our suggestions. Sizing the controller at panel watts / battery volts is our rule; Victron's ratings allow more panel per amp. The 12 V fridge is Dometic's CFX3 45 figure on a 32 °C day; yours may use more or less. The US sun hours are NREL's 1961-1990 station averages; the Canadian ones are NRCan's. The US Department of Energy appliance page is quoted from its archived copy, because energy.gov no longer serves it. Latitudes for Canadian places are approximate, for the tilt only. Panel, battery, controller, inverter and fuse sizes are common sizes we assume.

Sources

  1. Natural Resources Canada, Photovoltaic potential and solar resource maps of Canada, and its municipality database: mean daily insolation (kWh/m2) by month for south-facing panels at latitude and latitude + 15 degrees.
  2. NREL, Marion and Wilcox, Solar Radiation Data Manual for Flat-Plate and Concentrating Collectors (1994): monthly averages for 239 US stations, 1961-1990, at the same tilts.
  3. NREL, Dobos, PVWatts Version 5 Manual (2014), Table 6: default system losses 14%; and the PVWatts calculator (v8), which we ran for Ottawa and Phoenix.
  4. Victron Energy, lithium iron phosphate batteries Smart datasheet: round trip 92% (lead-acid 80%), 2,500 cycles at 80% depth of discharge, charge from +5 C. Victron, Energy Unlimited: lead-acid 80% capacity at -10 C. Phoenix Inverter datasheet: 92 to 95% maximum efficiency, 8 to 30 W no-load draw, 2,400 W peak on the 1,000 W unit. SmartSolar MPPT 100/30 and 100/50 datasheet: 98% maximum efficiency, 700 W of panels at 12 V on the 50 A unit. SmartSolar MPPT 150/70 up to 150/100 datasheet: 1,450 W of panels at 12 V on the 100 A unit; with more panel connected the controller limits its input.
  5. Dometic, CFX3 45: 1.03 Ah an hour at 12 V DC with 32 °C outside and 4 °C inside.
  6. Champion Power Equipment, Generator Wattage Chart (running and starting watts), Anker SOLIX (device averages) and Generac (motors start at 2 to 3 times running watts).
  7. US DOE Energy Saver, Estimating Appliance and Home Electronic Energy Use (archived 2026-07-01): watts x hours a day / 1,000 = kWh a day.

All pages read on November 17, 2026. General planning information; your installer and a licensed electrician size the final wiring, fuses and mounting.

About Off-Grid Solar Calculator

A small cabin using 858 Wh a day (six LED lights, phone and laptop charging, a 12 V fridge and a 12 V water pump) in Toronto, year-round on a 12 V LiFePO4 system with 2 days of battery, needs 3 x 200 W solar panels, 1 x 12 V 200 Ah LiFePO4 battery, 1 x 50 A MPPT charge controller and a 300 W pure sine inverter. Used June to August only, 3 x 100 W panels and one 30 A controller do it, because a December day there gives 2.35 hours of full sun and August 5.21.

By the ToolFluency team · Updated November 2026

List what you will run: LED lights, phone and laptop charging, a 12 V fridge, a 12 V water pump, a furnace blower, a CPAP, a router, a TV, or anything of your own with its label watts. Pick the nearest place in Canada or the US, whether you use it year-round or only in summer, how many days the battery must carry you with no sun, 12, 24 or 48 V, and LiFePO4 or lead-acid. You get one answer in whole parts: how many panels, how many batteries, the MPPT charge controller and the pure sine inverter. Under it is every step of the math, and a parts list with Have it and Bought ticks you can print or copy. Short outages at home are the Power Outage Plan; generators are the Generator Size Calculator.

How to size an off-grid solar system

  1. List what you will run. Each item has a typical watts figure you can change to the label on yours (volts x amps = watts), the hours it runs a day, and how many. Add your own items, and tick Has a motor for pumps, fans and compressors.
  2. Pick the nearest place. Canadian sun hours come from Natural Resources Canada, US from NREL.
  3. Pick Year-round or Summer only (June to August). Year-round sizes on the darkest month, with the panels tilted steep for winter sun.
  4. Set the days the battery must carry everything with no sun. 2 is our suggestion.
  5. Pick 12, 24 or 48 V and LiFePO4 or lead-acid (AGM), and a panel size or let it pick.
  6. Read the answer, check the numbers and How we worked this out, then print the parts list.

Hours of full sun a day on a south-facing panel: darkest month (tilt latitude + 15 degrees) and darkest summer month (tilt latitude)

PlaceDarkest monthJune to August
Toronto, ON2.35 (December)5.21 (August)
Ottawa, ON2.64 (November)5.12 (August)
Huntsville, ON2.34 (November)4.97 (August)
Montréal, QC2.68 (November)5.09 (August)
Calgary, AB3.07 (December)5.46 (June)
Vancouver, BC1.71 (December)4.87 (June)
Halifax, NS2.43 (December)4.79 (August)
Chicago, IL2.6 (December)5.5 (August)
Phoenix, AZ5.3 (December)6.9 (July)

Examples

Small cabin near Toronto, year-round
Six 10 W LED bulbs for 5 hours (300 Wh), a phone charge (10 Wh) and a laptop at 100 W for 2 hours (200 Wh) go through the inverter: 510 Wh. A 12 V fridge averaging 12.4 W all day (Dometic CFX3 45: 298 Wh) and a 100 W 12 V water pump for 30 minutes (50 Wh) run straight from the battery: 348 Wh. 510 / 0.90, plus a 300 W inverter's 8 W idle draw for the 5 hours the lights are on (our suggestion), plus 348 = 954 Wh from the battery. Two days at 80% for LiFePO4: 2,386 Wh, 199 Ah at 12 V, so 1 x 12 V 200 Ah. The battery needs 954 / 0.92 = 1,037 Wh put back a day; each panel watt gives 2.35 x 0.83 x 0.95 = 1.85 Wh in December, so 560 W: 3 x 200 W. Controller: 600 W / 12 V = 50 A, one 50 A.
The same cabin, June to August only
August is the darker summer month in Toronto: 5.21 hours at latitude tilt. Each panel watt gives 5.21 x 0.74 x 0.95 = 3.66 Wh, so 1,037 / 3.66 = 283 W: 3 x 100 W panels. Controller: 300 W / 12 V = 25 A, so one 30 A. The battery and the 300 W inverter stay the same, since they depend on what you run, not on the sun.
Same cabin on 24 V
The same 2,386 Wh is 99 Ah at 24 V, so 1 x 24 V 100 Ah LiFePO4. The panels stay at 3 x 200 W, but the controller current halves: 600 W / 24 V = 25 A, one 30 A controller. The 12 V pump then needs a 24 V to 12 V converter; the CFX3 runs on 24 V as well (Dometic). Higher voltage means less current, thinner cable and fewer controllers.

Frequently asked questions

How many solar panels do I need for a cabin?

Divide what the battery needs back each day by the sun in your darkest month. A cabin using 858 Wh a day near Toronto needs about 1,037 Wh a day put into a LiFePO4 battery; December gives 2.35 hours of full sun, and after PVWatts losses and the charge controller each panel watt makes about 1.85 Wh. That is 560 W, or 3 x 200 W panels year-round, and 3 x 100 W for summer only.

How many batteries do I need for off-grid solar?

Daily use from the battery x days with no sun, divided by how much of the battery you use. LiFePO4 is used to 80% (Victron rates its cells at 2,500 cycles at 80% depth of discharge); lead-acid to 50%, and year-round lead-acid also loses about 20% in the cold (Victron: 80% capacity at -10 C). 954 Wh a day for 2 days is 2,386 Wh of LiFePO4, 199 Ah at 12 V, or 4,771 Wh of lead-acid, 398 Ah.

What size charge controller do I need?

Panel watts divided by battery volts, because a controller's amps are what it puts into the battery. 600 W on a 12 V battery is 50 A, so one 50 A MPPT controller; on 24 V it is 25 A, so one 30 A. Makers rate each controller for more panel watts than that (Victron SmartSolar at 12 V: 50 A takes 700 W, 100 A takes 1,450 W), so check the maker's maximum PV watts at your battery voltage.

What size inverter do I need for a cabin?

Add the running watts of everything on 120 V that could be on at once and add 25%; then check its surge (about twice its rating) covers the biggest motor start. Six LED bulbs, a phone charger and a laptop charger run at 180 W; x 1.25 = 225 W, so a 300 W pure sine inverter. A 12 V fridge and a 12 V water pump wired to the battery skip the inverter, so they add nothing to it.

How many hours of sun do solar panels get in Canada in winter?

In December a south-facing panel tilted steep gets about 2.35 hours of full sun a day in Toronto, 1.71 in Vancouver, 3.07 in Calgary and 2.43 in Halifax (Natural Resources Canada). In the North it is under 1 hour: 0.74 in Whitehorse, 0.02 in Inuvik, where solar alone cannot carry the winter.

LiFePO4 or lead-acid for a cabin?

LiFePO4 lets you use 80% of its rating and returns 92% of what you put in; lead-acid is used to 50% and returns about 80% (Victron), so a lead-acid bank is about twice the amp-hours and needs more panels. LiFePO4 must not be charged below 5 C, so keep it in the heated space or buy one with a built-in heater.

Do I need an electrician for an off-grid solar system?

Anything wired into a building needs a permit and a licensed electrician under the Canadian Electrical Code or the NEC. The calculator gives the parts; the electrician sizes the cable, fuses and disconnects.
Disclaimer: General planning from Natural Resources Canada, NREL (Solar Radiation Data Manual, PVWatts), Victron Energy datasheets, Dometic, Champion and Anker, read on 2026-11-17. Sun figures are long-term averages and a real winter can be darker; snow, shade and a shallow tilt cut output. Pack and part sizes are common sizes we assume. Anything wired into a building needs a permit and a licensed electrician.

Part of ToolFluency’s library of free online tools for Survival & Off-Grid. No account needed, no data leaves your device.

Embed this tool on your site (free)
Paste this where you want the tool. Please keep the attribution link.
<iframe id="tf-off-grid-solar-calculator" src="https://toolfluency.com/tools-v2/survival/off-grid-solar-calculator.html?embed=1" width="100%" height="640" loading="lazy" style="border:1px solid #e2e2e2;border-radius:12px;max-width:760px" title="Off-Grid Solar Calculator by ToolFluency"></iframe>
<script>addEventListener("message",function(e){var f=document.getElementById("tf-off-grid-solar-calculator");if(f&&e.source===f.contentWindow&&e.data&&e.data.tfEmbedHeight){f.height=e.data.tfEmbedHeight}});</script>
<p>Powered by <a href="https://toolfluency.com/tools-v2/survival/off-grid-solar-calculator.html">Off-Grid Solar Calculator</a> — free tools by ToolFluency</p>