How to size a dehumidifier, and why the pints changed
Dehumidifiers are sized by capacity: how many pints of water they remove from the air in a day. You need more capacity for a bigger space and a wetter one. A sizing chart crosses the floor area with how damp the space is and gives a capacity.
The 2019 test change
DOE standards that took effect in June 2019 changed how capacity is measured. Portable units are now tested at 65 °F instead of 80 °F, to match a basement better. Cooler air holds less water, so a dehumidifier tested the new way reports a smaller capacity. From 2020 you will see units that look like older models but carry lower pint ratings. ENERGY STAR publishes a rough conversion, and says the real change varies by model:
| Old rating (through 2019), pints a day | New rating (2020 on), about |
| 30 | 20 |
| 40 | 25 |
| 50 | 30 |
| 55 | 30 to 35 |
| 60 | 35 |
| 70 | 40 to 45 |
| 90 | 55 |
Most sizing charts online, including the AHAM chart, still use the old numbers. That is why two pages can tell you sizes about twice apart. The calculator reads the AHAM chart, converts with this table (in a straight line between rows, and at the middle of the 30 to 35 and 40 to 45 ranges), and rounds up to a common size on today's boxes: 20, 22, 30, 35 or 50 pints.
The charts disagree
There is no single official chart. For a 1,000 sq ft, very damp space with an 8 ft ceiling, the AHAM chart gives 17 pints a day on the old test, which is under 20 on a 2020+ label. ENERGY STAR's own chart gives 25 to 40 pints. GE's chart points to its 35 pint unit. Frigidaire Canada's chart says 70 pints and does not say which test it uses. We follow the AHAM chart because AHAM is the appliance makers' industry association and its chart is the one retailers reprint. It is the smallest of the four, so the calculator never goes below the bottom of ENERGY STAR's range for your dampness level, and shows the ENERGY STAR and GE numbers next to its answer.
Ceiling height, basements and laundry
The charts assume an 8 ft ceiling. GE says to add 25% to the area for a 10 ft ceiling; the calculator scales the area in a straight line for other heights, which is our own extension of that rule. Basements in humid summers often need more than a chart gives (AlorAir), so the calculator goes one size up when you tick that box. ENERGY STAR lists laundry drying as a high-load condition in its Wet level, so laundry hung in the space counts as at least wet. Past 2,500 sq ft the AHAM chart stops: ENERGY STAR advises having a whole-home unit sized and installed by an HVAC contractor.
Humidity to aim for
Health Canada recommends keeping indoor relative humidity between 30% and 50% and running a dehumidifier in damp areas such as basements, and fixing the moisture source so mould does not come back. The US EPA says below 60%, ideally 30 to 50%. ENERGY STAR suggests 30 to 40% in cold weather to stop window condensation, and notes that ENERGY STAR certified dehumidifiers are 20% more efficient than models that are not certified.
Sources
- ENERGY STAR, Dehumidifier Testing and Capacity. The June 2019 DOE standards, the 65 °F test, and the old to new capacity table.
- ENERGY STAR, Dehumidifiers. Its sizing chart, water removal (bucket shutoff, hose, pump), operating temperature, humidity range and the 20% efficiency figure.
- Abt, Dehumidifier Buying Guide and AlorAir, What Size of Dehumidifier Do I Need. Both reprint the same AHAM sizing chart.
- GE Appliances, Dehumidifier Sizing. 22, 35 and 50 pint chart; 8 ft ceiling, add 25% for 10 ft.
- Frigidaire Canada, Dehumidifier sizing guide.
- Health Canada, Guide to addressing moisture and mould indoors.
- US EPA, A Brief Guide to Mold, Moisture and Your Home.
Pages read on November 16, 2026. We could not open the AHAM chart on aham.org; it is quoted as Abt and AlorAir reprint it, and both match.
About Dehumidifier Size Calculator
For a very damp 1,000 sq ft basement with an 8 ft ceiling, buy about 30 pints a day on a 2020+ label (sold as 50 pints before 2020). The AHAM sizing chart says 17 pints on the pre-2019 test, under 20 on a new label, but ENERGY STAR's chart starts at 25 for a very damp space, so 30 is the common size to buy. The numbers on the box dropped in 2020 because DOE now tests at 65 °F instead of 80 °F.
By the ToolFluency team · Updated November 2026
Enter the size of the room or basement, the ceiling height and how damp it is, using the four AHAM levels. The calculator reads the AHAM chart, converts its old-test pints to the pints printed on boxes since 2020 with ENERGY STAR's table, rounds to a size you can buy, and shows what the ENERGY STAR and GE charts say for the same space. Every number is cited in the sources below.
How to use
- Pick feet or metres. Enter the length and width of the space, or its total floor area, and the ceiling height.
- Pick how damp it is: moderately damp (musty in humid weather), very damp (smells and damp stains), wet (wet walls or seepage) or extremely wet (wet floors). A hygrometer reading helps you choose.
- Tick the boxes that fit: a basement with humid summers goes one size up; laundry dried in the space counts as at least wet; a space under 65 °F needs a low-temperature model.
- Pick how you will empty it: a bucket, a hose to a floor drain, or a pump.
- Read the size to buy on a 2020+ label, what that size was called before 2020, and what the other charts say.
- Set the humidistat to 50% or a little lower, and fix any water coming in.
AHAM dehumidifier sizing chart (pints a day, pre-2019 test), as reprinted by Abt and AlorAir
| Condition | 500 sq ft | 1,000 sq ft | 1,500 sq ft | 2,000 sq ft | 2,500 sq ft |
| Moderately damp: musty smell in humid weather | 10 | 14 | 18 | 22 | 26 |
| Very damp: smells, damp stains on walls and floors | 12 | 17 | 22 | 27 | 32 |
| Wet: wet walls and/or seepage | 14 | 20 | 26 | 32 | 38 |
| Extremely wet: wet floors, high-load conditions | 16 | 23 | 30 | 37 | 44 |
Examples
1,000 sq ft very damp basement, 8 ft ceiling
The AHAM chart gives 17 pints a day on the old test. ENERGY STAR's table starts at old 30 = new 20, so that is under 20 pints on a 2020+ label. ENERGY STAR's own chart says 25 to 40 pints for a very damp space, and the calculator never goes below the bottom of that range, so it rounds up to the next common size: buy about 30 pints on a 2020+ label (sold as 50 pints before 2020). Ticking humid summers gives the same 30 (one size up from 20). GE's chart says 35.
1,500 sq ft wet space, 10 ft ceiling
The 10 ft ceiling adds 25% (GE), so the area used is 1,875 sq ft. The AHAM wet row is 26 pints at 1,500 and 32 at 2,000 sq ft, so 30.5 pints on the old test. ENERGY STAR's table turns that into about 20.3 pints on a 2020+ label, rounded up to 22. ENERGY STAR's chart starts at 30 pints for a wet space, so the calculator raises it: buy about 30 pints on a 2020+ label (sold as 50 before 2020). GE's chart goes past its 50 pint unit.
20 x 25 ft moderately damp room
The AHAM chart gives 10 pints a day on the old test, under 20 on a 2020+ label. A 20 pint unit (sold as 30 pints before 2020) covers it. ENERGY STAR says 20 to 30 pints and GE says its 22 pint unit.
Frequently asked questions
What size dehumidifier do I need for a 1,000 sq ft basement?
For a very damp 1,000 sq ft basement with an 8 ft ceiling, buy about 30 pints a day on a 2020+ label (sold as 50 pints before 2020). The AHAM chart alone says 17 pints on the old test, under 20 on a new label, but ENERGY STAR's chart starts at 25 pints for a very damp space, so the calculator rounds up to 30, the next common size.
Why does a new 35 pint dehumidifier look like an old 60 pint one?
DOE standards that took effect in June 2019 test portable dehumidifiers at 65 °F instead of 80 °F. Cooler air holds less water, so the same machine gets a smaller rating. ENERGY STAR's table: old 30 is about new 20, old 50 about new 30, old 60 about new 35, old 70 about new 40 to 45.
How many square feet does a 50 pint dehumidifier cover?
It depends on which label the 50 is on and how damp the space is. GE's chart says its 50 pint unit (a 2020+ rating) covers 4,500 sq ft mildly damp, 2,000 sq ft very damp and 1,500 sq ft wet, with an 8 ft ceiling. An old 50 pint rating is only about 30 pints on today's label.
What humidity should I set my dehumidifier to?
Set it to 50% or a little lower. Health Canada recommends keeping indoor relative humidity between 30% and 50%. The US EPA says below 60%, ideally 30 to 50%. In cold weather ENERGY STAR suggests 30 to 40% to stop condensation on windows.
Does ceiling height change the size?
Yes. The charts assume an 8 ft ceiling. GE says to add 25% to the square footage for a 10 ft ceiling. The calculator scales the area in a straight line for other heights (height / 8), which is our extension of GE's rule. Under 8 ft it keeps the 8 ft figure.
Do I need a dehumidifier with a pump?
Only if it will run for long stretches and the drain is higher than the unit, such as a laundry sink, or far away. Otherwise a model with a hose fitting can drain into a floor drain or sump. With a bucket, most units shut off when it is full (ENERGY STAR) and you empty it by hand.
Which dehumidifier sizing chart is right?
There is no single official chart. For a very damp 1,000 sq ft space the AHAM chart gives 17 old pints (under 20 new), ENERGY STAR 25 to 40, GE 35, and Frigidaire Canada 70. We follow the AHAM chart because it is the appliance industry association's, never go below the bottom of ENERGY STAR's range, and show the others next to it.
Disclaimer: This is a buying estimate. The charts are approximate and disagree with each other; ENERGY STAR calls its own old-to-new table a rough correlation that varies by model. Water coming through walls or floors needs its source fixed. Whole-home units should be sized and installed by an HVAC contractor. No one has reviewed this page for your home.